5.Automatic Operation
Posted Date:2026.01.13 Browse Number:0The automatic operation function provides a program for setting up and initiating automated curing cycles. Being fully configurable, the program can be customized to meet the specific requirements of different clients.
The recipe steps include vacuum connection to the product, product loading, integrity checks (such as leak testing and on-site inspection), as well as any other procedures that the client may wish to incorporate into the automation sequence.

The automatic operation interface displays the following information:
Operation Status: Indicates the current status of the workflow, showing either Stopped or Running.
Recipe Information: Displays the name and description of the active recipe.
Stage Information: Shows the current stage of operation, e.g., Stage 1.
Stage Description: Provides a descriptive label for the current stage, e.g., Cooling Stage, Heating Stage, Holding Stage, etc.
Total Operation Time (min): Indicates the elapsed time of the entire recipe in minutes.
Stage Operation Time (min): Indicates the elapsed time of the current stage in minutes.
How to Set Up and Initiate Operation