Introduction
SINOMAC working process of medical waste treatment autoclave.
1. Waste loading
The infectious waste is loaded into the loading trollery and transmitted to the autoclave for treatment; after closing the door automatically or manually, the operator can press the start button to run the automatic program and handle the waste.
2. Processing procedure
After the door is closed, the next process is automatically executed by the preset program.
Stage 1: it is the pre-pumping vacuum process.
Stage 2: through the steam heating and pressure, disinfection and sterilization.
Stage 3: Cooling of the high-temperature steam.
Stage 4:In the post-vacuum treatment stage, the residual steam and condensate in the sterilization warehouse are removed, and the waste is dried.
Stage 5: the atmosphere enters the sterilization warehouse to achieve the effect of the warehouse decompression.
3. Unload
Once the treatment is finished, the autoclave will light up a green light to indicate that the operation cycle has been completed, and then open the door, by the operator to start the unloading operation, remove the treated waste, after crushing and compaction as the general household garbage into the landfill landfill or recycling.
Features
Advanced Technology
Hydraulic quick door, with mechanical, electronic double safety interlock protection
Powerful vacuum pump or vacuum generator
Equipped with automatic PLC control system and recorder
Energy Efficiency
Minimize steam consumption
No additional sewage and waste gas treatment is required
Power saving
Pro-environment
High temperature instantaneous sterilization technology, odorless exhaust gas and standard emission.
Waste liquid isolation technology, waste liquid and condensate water isolation and no waste liquid discharge.
No harmful substances are emitted.
Convenient, Safe
Liquid Handling & Robotics
No contact with clinical waste during operation and maintenance.
Adopt multiple protection system to ensure safety.
High-activity processing
Sterilization rate exceeds log4 (99.99%).
After vacuum and steam heat treatment, the waste volume can be reduced by 40% to 60%.
When water is removed, the weight of the waste is reduced by 20%.
Low operation cost
Service life is 15 years
Small investment, easy maintenance, low operating cost.
Parameter
MODEL | Inner Diameter | Working Length | Capacity |
SN-YLGF100 | 1000mm | 1800mm | 100kg |
SN-YLGF200 | 1250mm | 2500mm | 200kg |
SN-YLGF250 | 1650mm | 2500mm | 250kg |
SN-YLGF300 | 1650mm | 3000mm | 300kg |
SN-YLGF400 | 1650mm | 4000mm | 400kg |
SN-YLGF500 | 1650mm | 5000mm | 500kg |
SN-YLGF600 | 1650mm | 6000mm | 600kg |
SN-YLGF800 | 2000mm | 6000mm | 800kg |
SN-YLGF900 | 1650mm | 9000mm | 900kg |
SN-YLGF1100 | 2000mm | 8000mm | 1100kg |
SN-YLGF1400 | 2000mm | 10000mm | 1400kg |
SN-YLGF1600 | 2000mm | 12000mm | 1600kg |